D7212GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 96
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Two relays can activate when this point
enters into alarm if the P## Rly Resp Type
for this point is programmed.
Use these codes to activate relays on the
D8129 OctoRelay (or C8137 Transmitter
Interface). You can assign the same code
to several points providing a summary zone
alarm output. When the point enters into
alarm, the relay activates. When the alarm
is acknowledged and is no longer scrolling
in the keypad display, the relay resets.
P### Point Text
Default: Refer to the program record sheet
Selection:
Up to sixteen alphanumeric
characters
Enter alphabetic characters (A to Z) in capital letters.
Enter up to sixteen characters of text to describe the
point. This point text is shown at keypads, if the point
is programmed as visible, and sent to the D6500 or
D6600 when transmitting in Modem IIIa
2
format (if it
is a reporting point).
Include the point number in custom point text. This
helps the user when viewing events, creating bypasses,
and so on. It can also simplify troubleshooting.
When a D1260 Keypad is installed on the
system, the point text for Points 240 to 243
can be used for Area Name Text for Areas
1 to 4, respectively. Refer to Table 29:
Table 29: Point Text for Points 240 to 243
Point Text Corresponding Area Name Text
Point 240 Area 1
Point 241 Area 2
Point 242 Area 3
Point 243 Area 4
4.4 COMMAND 7 and COMMAND 9
These entries assign point indexes, BFSK report code,
BFSK relay that activates, and the text for the
COMMAND 7 and COMMAND 9 keypad functions.
CMD7 Point Index
Default: 31
Selection: Blank (00) to 31
This entry selects one of the 31
P## Index
codes that
define how the control panel reacts when a
COMMAND 7 is initiated (refer to the
P###
BFSK/Relay
prompt on page 95).
The point index code used for COMMAND
7 must not be used for any other points on
the system.
CMD7 BFSK/Relay
Default: 1
Selection: 0 to 9
This entry selects one of the digits shown for reporting
in BFSK or for activating relays 9 to 16 for the
D7212GV2 when COMMAND 7 is initiated (refer to
the
P### BFSK/Relay
prompt on page 95).
COMMAND 7 does not activate the
Summary Fire Alarm relay.
CMD7 Point Text
Default: [COMMAND][7]
Selection:
Up to sixteen alphanumeric
characters
Enter alphabetic characters A to Z in capital letters
Enter up to sixteen characters of text to describe the
point. This point text appears at keypads (if the point is
programmed as visible) and sent to the D6500 or
D6600 when transmitting in Modem IIIa
2
format (if it
is a reporting point).