D7212GV2 | Program Entry Guide | 3.0 RADXUSR1 EN | 77
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Figure 4: User Group 122 Example
Master User:
ID 122
.
♦ CRD ID 122-0
♦
Sub User -1: ID 122-1
CRD ID 122-1
♦
Sub User -2: ID 122-2.
CRD ID 122-2
♦
Sub User -3: ID 122-3.
CRD ID 122-3
1 - User passcode
2 - User token or card
In reporting systems using modem format, all three digits of the User ID Code are transmitted to the
central station with appropriate reports. Central station automation computer systems can accept only
Zonex and Comex style User IDs. Refer to Point/User Flag in Section 2.1 Phone on page 8.
In BFSK, only one number is transmitted. This number represents a group of ten users as shown in Table 26.
Users 100 through 249 do not report in BFSK format.
Table 26: BSFK User Code Report
User
Code
000 to 009
User
Code
010 to 019
User
Code
020 to 029
User
Code
030 to 039
User
Code
040 to 049
User
Code
050 to 059
User
Code
060 to 069
User
Code
070 to 079
User
Code
080 to 089
User
Code
090 to 099
BFSK
Report
0
BFSK
Report
1
BFSK
Report
2
BFSK
Report
3
BFSK
Report
4
BFSK
Report
5
BFSK
Report
6
BFSK
Report
7
BFSK
Report
8
BFSK
Report
9
User ###
Default: 001
Selection: 000 or 001 to 099
Enter the User number you are programming.
User 000 is the Service Authority Level
(Level 15). You cannot change the
programming for user 000.
Only the Service Authority Level (User 000)
can delete User 000. When a user other
than User 000 tries to delete the passcode
for User 000, the keypad displays NOT IN
USE.
User 000 cannot be added or changed at
the keypad whether it exists or not.