D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 59
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Add User
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
18 Add User [COMMAND][5][6]
Use this function to add or change passcodes, add or
change tokens or cards and Sub-users, and add or
change control panel authority levels (L##) by area.
Del User
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
19 Delete User [COMMAND][5][3]
Use this function to delete a user’s passcode and
tokens or cards. It does not delete user names.
This function deletes the passcode, master
user, and all sub-users associated with the
user number.
Extend Close
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
20 Extend Close [COMMAND][5][1]
Use this function to change the expected closing time
for the area. The window cannot be adjusted until the
Close Early Begin time passes and the Closing
Window is active.
View Log
Default: E
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
21 View Log (Menu function only)
Use this function to view all of the system events, their
time stamps, User IDs, or point numbers. User Name
and Point Text are not stored in the event log, but
they appear when the control panel matches them with
the User ID ### and the Point ###.
Each event appears on one line in the log. Any
information related to that event appears on a separate
line in the log.
Because events in the log are not uniform in length,
the control panel can store from 500 to 1000 events.
Print Log
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
22 Print Event Log (Menu function only)
Use this function to print all the events stored in the
control panel beginning at the start date and ending
with the last event in the log.
User Cmd 7
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
23 User COMMAND
7
[COMMAND][7]
Use this function to activate an alarm programmed in
COMMAND 7 in the RADXPNTS Handler.
User Cmd 9
Default: P
Selection:
Blank, E, or P
Function No. Function Name Alternate Keystroke
24 User COMMAND
9
[COMMAND][9]
Use this function to activate an alarm programmed in
COMMAND 9 in the RADXPNTS Handler.