D7212GV2 | Program Entry Guide | 3.0 RADXUSR1 EN | 78
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
U### Passcode
Default: Refer to the program record sheet
Selection: Three to six digits ( 0 to 9)
Enter three to six digits to enable a passcode for the
master user in this group.
User I.D.000 is the reserved user for service
personnel. The default service passcode is
123.
The programmer does not allow you to
enter any passcode number that might
conflict with a duress passcode. The
programmer reserves the actual duress
passcode and the duress pass-code
number plus 1, duress pass-code number
plus 2, duress passcode-number minus 1,
and duress pass-code number minus 2.
If Duress Type is set to 1, passcodes
within a range of 1 for existing passcodes
cannot be entered. If Duress Type is set to
2, passcodes within a range of 2 cannot be
entered. This rule applies even if duress is
disabled. For example, with Duress Type
set to 2, when a passcode of 654321 is
entered, 654322, 654323, 654320, and
654329 are reserved and are not available
to other users.
The authority to silence a bell is granted to
all passcodes regardless of their authority
level assignments. A user passcode can
silence a Fire or Burg bell as long as any
authority level is assigned to the area
where the bell can be silenced.
U### User Group
Default: Blank
Selection: Blank, 1 to 8
Create a group of up to 099 users whose combinations
can be enabled and disabled using an automatic user
window. This is the number entered into the
W# User
Group
for any active
W# User Window
. Multiple
windows can be programmed for one user group (up
to eight) within one 24-hour period. For example, if
User Group 1 has a window running from 8:00 AM
(start time) to 4:00 PM (stop time), the users for that
group can use their passcodes only between that time.
Between 4:00 PM that day and 8:00 AM the next day,
the users cannot use their passcodes.
To enable this user’s passcode at all times,
leave U### User Group blank.
User Group Window times cannot be changed from
the keypad. When a window is assigned to a user
group, the users in that group rely on the window to
be active (within the start and stop times) for their
passcodes to function. The only way to disable the
window is by reprogramming the control panel from
the D5200 or remote programming software (RPS).
U### Area 1 [through Area 4] Auth
Default: Refer to the program record sheet
Selection: 1 to 14 or Blank
Assign an authority level to the user for this area.
Blank means the user has no authority in this area.
U### Name
Default: Refer to the program record sheet
Selection: Sixteen alphanumeric characters
Enter Alphabetic-characters A to Z in capital letters
Period (.), comma (,), percent (%), parentheses [()],
equal (=), greater or less than (< >), exclamation (!),
braces ({}), apostrophe (’), carat (^), grave accent (`),
tilde (~), semi-colon (;), and colon (:) are not allowed.
Enter up to sixteen characters of text for this user
group.
Programming this group with a
departmental, team, or function name
identifies all the users in this group in a
function related manner, such as
ENGINEERING.
U### Mstr Site
Default: Blank
Selection: 000 = (0) to 254 or Blank (255)
This feature is not available with the D7212GV2.
Keep the default setting.