2.9.5 Open/Close Options
Programming determines if Opening, All Normal
Closing, and Force Arm/Bypass Closing Events are
sent to the remote central station. Without remote
reports, all control panel and area arming (Closing
Events) and disarming (Opening Events) default to
local events.
Use this programming category to determine which
opening and closing supervision characteristics are
needed.
There are three ways to generate reports from the
control panel. You can generate reports by account, by
area, or a combination of both.
To suppress reports:
• Use Opening/Closing Windows to suppress
reports for a specified period of time and then
automatically turn them on again.
• Use the Restricted O/C options. A Closing Report
is sent if the user is force arming, sending duress,
or bypass arming. An Opening Report is sent if
the user is disarming during an alarm condition or
unbypasses points when disarming. If the system is
normal, no Opening or Closing Report is sent.
For the scheduled suppression of Opening
and Closing Reports, refer to Section
5.1.1 Opening and Closing) to define
Opening and Closing Windows.
Account Opening and Closing Reports
Opening and Closing Reports are sent by account
when the last area in a group of areas with the same
account number(s) is armed.
Area Opening and Closing Reports
Closing Reports are sent for each area as it is armed.
The account number is also sent for each area.
Customizing Account Opening and Closing Reports
You can eliminate area Opening and Closing Reports
from selected areas in the account by programming
A# Area O/C
as No for those areas.
Combination Account and Area Opening and
Closing Reports
To send both account openings and closings, and
individual area openings and closings for all areas in
the account, you must:
• Program
A# Acct O/C
as Yes for all areas in the
account.
• Program
A# Area O/C
as Yes for all areas in the
account.
Closing Reports: When areas in the account are
independently armed, each area generates an Area
Closing Report. When the last area is armed, it also
generates an Account Closing Report.
Opening Reports: When the first area in the account
is disarmed, it generates an Account Opening Report
along with an Area Opening Report. When the
remaining areas in the account are disarmed, each area
generates an Area Opening Report.
Area Only Opening, Closing Supervision Features
Use these features to supervise opening and closing
activity by area. Auto Close, Fail To Open, and Fail
To Close all work independently of the
A# Acct O/C
feature. To use these features, program O/C Windows.
Area
Default: 1
Selection:
1 to 4
Enter the area number you are programming.