D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 68
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
The test ends when all points are tested, or if the
test times out after ten min of no activity.
Local event printing occurs without alarm
annunciation or reports sent to the central station
receiver.
The D1255 Keypad shows a sequential count and
text related to the point after each point is
actrivated and restored.
The keypad shows All PTS TESTED. An All
Points Tested Event is sent to the central station
receiver (if programmed) when the last point is
tested.
Walk Start and Walk End Reports are sent to the
central station receiver for the beginning and end
of the test (if programmed in phone routing).
Custom Functions
L## C Function 128 [through 131]
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
128 through
13
Enable Custom
Function 128
through 131
(Menu function only)
Execute the desired Custom Function.
Report Levels
L## Force Arm
Default: Refer to the program record sheet
Selection: Blank or E
A user with this authority level can Force Arm.
L## Area O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates Opening and Closing Reports if the area
where this authority level is assigned sends Opening
and Closing Reports.
L## Restricted O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates an Opening Report if a bell is ringing or a
Closing Report when force or bypass arming. The area
where this authority level is assigned must be
programmed for restricted openings and closings (refer
to the
A# Restrictd
O/C
prompt in Section 2.9.5
Open/Close Options on page 40.
L## Perimeter O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates Perimeter Opening and Closing Reports if
the area where this authority level is assigned sends
Perimeter Opening and Closing Reports. Refer to the
A# Perimeter O/C
prompt on page 43.
L## Send Duress
Default: Refer to the program record sheet
Selection: Blank or E
Generates a Duress Report if the area where this
authority level is assigned sends duress. Refer to the
A# Duress Enable
prompt on page 35.
L## Passcode Arm
Default: Refer to the program record sheet
Selection: Blank or E
Arm an area by entering a passcode and pressing
[ENTER].
L## Passcode Disarm
Default: Refer to the program record sheet
Selection: Blank or E
Disarm an area by entering a passcode and pressing
[ENTER].
2.11.5 Access Control Levels
L## Security Level
Default: Refer to the program record sheet
Selection: M, P, D, or Blank
This feature is not available with the D7212GV2. Keep
the default setting.