D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 68
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
• The test ends when all points are tested, or if the
test times out after ten min of no activity.
• Local event printing occurs without alarm
annunciation or reports sent to the central station
receiver.
• The D1255 Keypad shows a sequential count and
text related to the point after each point is
actrivated and restored.
• The keypad shows All PTS TESTED. An All
Points Tested Event is sent to the central station
receiver (if programmed) when the last point is
tested.
• Walk Start and Walk End Reports are sent to the
central station receiver for the beginning and end
of the test (if programmed in phone routing).
Custom Functions
L## C Function 128 [through 131]
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
128 through
13
Enable Custom
Function 128
through 131
(Menu function only)
Execute the desired Custom Function.
Report Levels
L## Force Arm
Default: Refer to the program record sheet
Selection: Blank or E
A user with this authority level can Force Arm.
L## Area O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates Opening and Closing Reports if the area
where this authority level is assigned sends Opening
and Closing Reports.
L## Restricted O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates an Opening Report if a bell is ringing or a
Closing Report when force or bypass arming. The area
where this authority level is assigned must be
programmed for restricted openings and closings (refer
to the
A# Restrictd
O/C
prompt in Section 2.9.5
Open/Close Options on page 40.
L## Perimeter O/C
Default: Refer to the program record sheet
Selection: Blank or E
Generates Perimeter Opening and Closing Reports if
the area where this authority level is assigned sends
Perimeter Opening and Closing Reports. Refer to the
A# Perimeter O/C
prompt on page 43.
L## Send Duress
Default: Refer to the program record sheet
Selection: Blank or E
Generates a Duress Report if the area where this
authority level is assigned sends duress. Refer to the
A# Duress Enable
prompt on page 35.
L## Passcode Arm
Default: Refer to the program record sheet
Selection: Blank or E
Arm an area by entering a passcode and pressing
[ENTER].
L## Passcode Disarm
Default: Refer to the program record sheet
Selection: Blank or E
Disarm an area by entering a passcode and pressing
[ENTER].
2.11.5 Access Control Levels
L## Security Level
Default: Refer to the program record sheet
Selection: M, P, D, or Blank
This feature is not available with the D7212GV2. Keep
the default setting.
Comentarios a estos manuales