D7212GV2 | Program Entry Guide | 4.0 RADXPNTS EN | 94
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
4.3 Point Assignments
These entries assign point indexes to Points 1 to 40 for
the D7212GV2, and assign the points to the areas.
Also included in this section are parameters used to set
the point’s debounce count, BFSK/Relay (for use when
transmitting in BFSK or assigning relays to follow
alarms for a group of points), and custom keypad and
report text for each point.
Point Number
Default: 1
Selection: 1 to 40
Enter the point number you are programming. When
transmitting in Modem IIIa
2
, the three-digit point
number is reported to the D6500 or D6600. When
transmitting in BFSK, you must assign a zone number
in BFSK/Relay.
Point number 128 is reserved for
supervising Zonex 1.
P### Point Index
Default: Refer to the program record sheet
Selection: Blank (00) to 31
This entry selects one of the 31
P## Index
codes that
define the point’s characteristics and determines how
the control panel responds to various point conditions.
Blank (00) disables the point.
Missing Point Report
If a Point Index is assigned to a point that has an
incorrect address or that is not connected to the point
bus, a Missing Point Report occurs.
When a POPIT is missing, the control panel generates
the following responses based on the point type:
Fire points generate missing trouble responses.
Non-fire 24-hour points generate missing alarm
responses.
Non-fire, non 24-hour points generate missing
alarm responses while armed, and trouble
responses while disarmed. Exception: Non-fire,
non-24-hour points with a point response of 9 to D
generate a missing alarm response while disarmed.
POPIT modules monitor their sensor loops for three
conditions: loop normal, loop open, and loop shorted.
They send reports on these three conditions to the
control panel. The control panel uses point
programming to interpret the sensor loop information
sent by the POPITs and to make the appropriate
system response.
P### Area Assign
Default: 1
Selection: 1 to 4
The areas are numbered 1 to 4. Select the area numbr
to which the point is assigned.
The D7212GV2 allows programming for
Areas 1 through 4 only.
The D5200 Programmer allows entries
for Areas 5 through 8, but they cannot be
used on the D7212GV2.
If Areas 5 through 8 are programmed for
the D7212GV2, the keypad displays
CALL FOR SERVICE.