D7212GV2 | Program Entry Guide | 7.0 SIA CP-01 Quick Reference EN | 133
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
7.0 SIA CP-01 Quick Reference
Table 40: Programming the Control Panels for SIA CP--01 Compliance
Prompt Name Bosch Recommended Settings
for SIA CP-01 Compliance
Shipping Default References
Phone # (Prefix backup phone number with
Call Waiting disable command)
{Blank} Page 8
Duress Type Option 3 0 (disabled) Page 31
Cancel Report Yes Yes Page 31
A# Exit Dly Time 45 sec to 255 sec 60 sec Page 33
A# Duress Enable Yes No Page 35
A# Exit Restart Yes or No Yes Page 45
A# Arm No Exit Yes or No Yes Page 46
A# Two Man Rule No No Page 44
A# Early Ambush No No Page 45
A# Exit Warning Yes Yes Page 46
A# Entry Warning Yes Yes Page 46
A# Burg Time
1
6 min to 90 min 6 min Page 39
A# Alarm Bell 1 to 128(64), A, B, C A (on-board alarm output) Page 71
CC# Entry Tone Yes or No Yes Page 49
CC# Exit Tone Yes or No Yes Page 49
CC# Abort Display Yes or No Yes Page 51
CC# Cancel Display Yes or No Yes Page 51
Master Arm Inst {Blank} {Blank} Page 56
Perim Instant {Blank} {Blank} Page 56
L## Send Duress [Blank] or E
E
2
Page 68
L## Disarm [Blank] or E
E
2
Page 62
L## Passcode Disarm [Blank] or E
E
2
Page 68
P## Entry Delay 30 sec to 240 sec 30 sec Page 86
P## Alarm Abort Yes or No
Yes
3
Page 93
Abort Window 15 sec to 45 sec 30 sec Page 130
Passcode Length 3 to 6 digits Disabled Page 130
Swinger Count 1 to 2 trips 1 trip Page 131
Remote Warning Yes Yes Page 131
Cross Point Time 5 to 255 sec 20 sec Page 132
P## Cross Point Yes or No No Page 92
1 The SIA allowed range is 1 min to 90 min.
2 L14 is the default duress user index.
3 The default for P## Alarm Abort is No for P3, P4, P5, and P22.