D7212GV2 | Program Entry Guide | 1.0 Introduction EN | 7
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
1.4 Programming the Control Panel with
the D5200 Programmer
Caution: Do not connect the D5200 to
the PROG connector without closing the
reset switch. Doing so causes SDI ##
TROUBLE and CALL FOR SERVICE to
display on the keypads.
To acquire an update for your D5200
Programmer, call the Bosch Security
Systems, Inc. Handler Update System at
(800) 657-4584. Make a separate phone
call for each handler.
Use an analog telephone line with the
D5200. The D5200 dials only pulses.
Refer to Section 10 Updating Handlers in
the D5200 Programmer Operation Manual
(P/N: 74-06176-000-B) for details on
updating handlers.
• To connect the D5200 Programmer to the control
panel:
1. Close the reset switch, located in the upper
right corner of the control panel and labeled
S1 Reset, to place the D7212GV2 Control
Panel in the standby mode.
2. Connect the Molex® connector at one end of
the cord to the connector labeled PROG on
the PCB and PROG CONN on the faceplate.
• To retrieve the current control panel configuration,
press the [RECV (COPY)] key on the D5200 at the
NEWRECORD prompt. Refer to the D5200
Programmer Operation Manual (P/N: 74-06176-000)
for detailed information.
• To write new configuration information for the
control panel, press the [SEND (LOAD)] key at the
NEWRECORD prompt. Refer to the D5200
Programmer Operation Manual (P/N: 74-06176-000)
for detailed information.
• To disconnect the D5200:
1. Disconnect the the Molex® connector.
2. Open the reset switch.
When the reset switch is opened, the
control panel reboots and resumes normal
operation within 5 to 25 sec.
Table 3: Programming Error Displays
Display Description
INCOMPATIBLE
PANEL
You are connected to the
wrong control panel or using
the wrong handler. Check the
faceplate for the model number
and the handler title.
CHECK
CORD/RESET PIN
Check the cord and the reset
pin