D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 33
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
Programming Ten-Digit Account Numbers
To program a ten-digit account number (such as
1122334455) using the D5200 Programmer, you must
enter a character for each of the ten digits. Refer to
Table 20.
Table 20: Programming Ten Digit Account
Numbers
D5200 Programmer
A# Acct# Dgt 1&2 1 1
A# Acct# Dgt 3&4 2 2
A# Acct# Dgt 5&6 3 3
A# Acct# Dgt 7&8 4 4
A# Acct# Dgt 9&10 5 5
The D5200 account number entry shown in Table 20
appears in RPS as shown in Figure 2 on page 33.
Figure 2: Account Number Entry
22 33 44 5511
2
3 4 5 6 7
1
1 - RPS account number entry
2 - Corresponding D5200 account number digits
3 - Digits 1 and 2
4 - Digits 3 and 4
5 - Digits 5 and 6
6 - Digits 7 and 8
7 - Digits 9 and 10
Although the D5200 allows the character
“A” to be entered into the account, do not
use this character for the account number.
A# FA Bypass Max
Default: 1
Selection:
0 to 99
Specify the maximum number of combined Controlled
points that can be faulted or bypassed when arming
this area.
Refer to the prompts
P## FA Retrnable
and
P## BA
Retrnable
in Section 4.2 Point Responses on page 84 for
returning a point to the system when the point returns
to normal or when the area is disarmed.
Users can bypass more points than the
number entered here during the disarmed
state. It is only when the user attempts to
Bypass Arm an area (or areas) that this
restriction is enforced.
A# Delay Res
Default: No
Selection:
Yes or No
Yes Point Restoral Report is not sent until
the bell time expires or user
acknowledges alarm condition.
No
Restoral Reports are sent when point
restores, regardless of bell time.
A# Exit Tone
Default: Yes
Selection:
Yes or No
Sounds an exit tone during exit delay at all keypads
assigned to this area.
You can turn off exit tones for individual
keypads by programming the appropriate
CC# 1 to 8 as No in CC# Exit Tone.
A# Exit Dly Time
Default: 60
Selection:
Blank (0) to 600 ( in 5 sec
increments)
Exit delay time for this area when Master Exit or
Perimeter Exit arming.
Points programmed for instant alarm
response generate alarms immediately,
even during exit delay. To avoid instant
alarms on points adjacent to the perimeter
when leaving the area, program P##
Type in the Point Index as 3 (Interior
Follower).
For SIA CP-01 Compliance
The Exit Delay Time must be between 45 sec and
255 sec.