Bosch D7212GV2 Guía de instalación Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 140
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
D7212GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 41
Bosch Security Systems, Inc. | 1/08 | F01U003804-04
A# Acct O/C
Default: No
Selection:
Yes or No
Yes Send Opening and Closing Reports by
account.
Use this selection if the control panel
sends reports to an automation system
that cannot interpret multiple Area
Opening and Closing Reports, or if
Modem Format
is programmed as No
in the Phone category (BFSK format is
used and Opening and Closing Reports
are enabled).
An Account Opening Report is
generated when the first area in an
account is opened (disarmed). After the
Account Opening Report is sent,
disarming other areas in the account
does not generate another Account
Opening Report. An Account Closing
Report is generated only when the last
area in an account is closed (armed).
Opening and Closing Reports for
accounts do not contain any area
information.
Opening and Closing Windows
affect Account Opening and Closing
Reports: If an account opening or
closing is generated while an Opening
or Closing Window for this area is in
effect, and
Disable O/C
in Window is
programmed Yes, the report is not
sent. Use the same opening and closing
window times for all areas sharing the
same account number.
No Do not send Opening and Closing
Reports by account.
Determines if this area generates Account Opening
and Closing Reports. Program this item the same for
all areas in the account.
A# Area O/C
Default: Yes
Selection:
Yes or No
Yes Include the Area # and generate Opening and
Closing Reports for this area when it is armed.
No Do not include the Area # or generate
Opening and Closing Reports for this area.
Determines if the area number and the account
number are reported at arming and disarming. As long
as
Account O/C
is No, the account number sends a
report when arming this area individually. If
Account
O/C
is Yes, all areas with the same account number
must also be armed.
An Area Opening Report is generated when each area
is opened (disarmed). An Area Closing Report is
generated when each individual area is closed (armed).
Do not program this item as Yes if the
control panel reports to an automation
system that cannot interpret multiple Area
Opening and Closing Reports.
A# Disable O/C in Window
Default: Yes
Selection:
Yes or No
Yes Do not send Opening and Closing Reports
to the central station if they occur inside an
active window.
If an Opening or Closing Report occurs
outside a window, send it with an early or
late modifier. Refer to Section 5.1.1 Opening
and Closing on page 98.
The active window must be a Closing
Window for Closing Reports. It must be an
Opening Window for Opening Reports.
No Send Opening and Closing Reports to the
central station even when they occur inside a
programmed window. If an opening or
closing occurs outside of the appropriate
window, it reports but does not have an
early or late modifier.
If you want to monitor all opening and
closing activity and use features provided by
Opening and Closing Windows, program
this item as No, and program the
appropriate O/C Windows.