2.10.2 Area Text
Use this programming category to create custom Idle
Text displays for the keypads.
Each display can be programmed with up
to sixteen alphanumeric characters,
including: A to Z, 0 to 9, ?, &, @, -, *, +,
$, #, _, /.
Characters not listed are invalid and cannot
be used for text.
Area
Default: 1
Selection:
1 to 4
Enter the area number you are programming.
The D7212GV2 allows programming for
Areas 1 through 4 only.
The D5200 Programmer allows entries
for Areas 5 through 8, but they cannot be
used on the D7212GV2.
If Areas 5 through 8 are programmed for
the D7212GV2, the keypad displays
CALL FOR SERVICE.
Area# Is On
Default: Refer to the program record sheet
Selection:
Sixteen alphanumeric characters
Enter the text for this area that appears when:
the area is master armed or master instant armed,
and
other areas sharing the same account number are
not yet master armed.
This display does not appear when the area is
perimeter armed.
Area# Not Ready
Default: Refer to the program record sheet
Selection:
Sixteen alphanumeric characters
Enter the text for this area that displays when the area
is disarmed but points are faulted.
Area# Is Off
Default: Refer to the program record sheet
Selection:
Sixteen alphanumeric characters
Enter the text for this area that displays when the area
is disarmed and no points are faulted.
Area# Acct Is On
Default: Refer to the program record sheet
Selection:
Sixteen alphanumeric characters
Enter the text that appears when all areas sharing the
same account number are master armed. The ACCT
IS ON text appears at all keypads assigned to these
areas, if more than one area has the same account
number. The ACCT IS ON text also appears if only
one area in the system is used. Refer to the prompts
CC# Area Assign
and
Area # Acct Is On
in Section
2.10.1 Keypad (Command Center) Assignment on page 46.
When all areas in the account are master armed, the
Area # Is On text is replaced by the ACCT IS ON
text if the area is armed before all other areas with the
same account number.
Blank Entry
A blank entry disables the ACCT IS ON display for
this area. An account wide area shows the AREA # IS
ON text instead of the ACCT IS ON text.
Unique ACCT IS ON Text
Each area can have unique ACCT IS ON text, or you
can program the same text in each area of the account
so when all the areas in the account are armed, they all
show the same text.
D1260 Alpha V Keypad
Although it is not programmed in this area, the D1260
Alpha V Keypad can display up to sixteen characters
for an Area Name on line 1 of its display. The Area
Text (
Area # Is Off
,
Area # Not Ready
,
Area # Is
On
, and
Acct # Is On
) programmed in this module
appears on line 2 of the D1260 Alpha V Keypad.
When programming custom text, it should be logical
to users viewing it on the D1260. For example, the
Area Name Text can be programmed to display
Front Office and the
Area # Is Off
text
(programmed in this section) could be programmed to
display Ready To Arm. The D1260 would then show
on line 1 Front Office and on line 2, Ready To
Arm.